View Mobile No.

our range

Cooling Towers

Our range of products include cooling towers, 200tr square cooling tower, fanless cooling towers and oil type heat exchangers.
Cooling Towers

Cooling Towers

Price on Request
Tower MaterialWooden
Motor Power5HP
Supply Voltage440
Supply PhaseThree Phase
Cooling Capacity (in tons)150TR
Flow Rate (L/min)1000
Inlet temperature (degree Celsius)40
Outlet temperature (degree Celsius)30
Tower DesignOpen Loop
Tower TypeInduced Draft, Forced Draft
WELLTECH cooling tower manufacturer as customer design as per Cooling Tower 15TR Cooling Tower Welltech 20TR Cooling Tower Welltech 30TR Cooling Tower Welltech 40TR Cooling Tower Welltech 50TR Cooling Tower Welltech 60TR Cooling Tower Welltech 80TR Cooling Tower Welltech 100TR Cooling Tower Welltech 150TR Cooling Tower Welltech 200TR Cooling Tower Welltech 250TR Cooling Tower Welltech 300TR Cooling Tower Welltech 400TR Cooling tower Welltech

View Complete details

get quoterequest a call back
200TR Square Cooling Tower

200TR Square Cooling Tower

Rs 1.7 Lakh  / NumberGet Best Price
TypeInduced Draft Type, Forced Draft Type, Natural Draft Type
Tower MaterialFRP, RCC, Wooden
Supply PhaseThree Phase
The FRP Square Type Cooling Towers consists of Honey comb PVC fills and eliminators in a design that maximizes economy and efficiency and directly driven fan and Motor with spray Nozzles 'Minimum drifts Losses. Hot dipped Galvanized hardware with rectangular casing body in elegant design. FRP Square type Cooling Towers operates on the induced draft counter flow principle operation. The fan creates air movement vertically pulled upwards on tower across the fills in opposition to the water flow. Hot circulating water enters the water inlet headers and sprays through non clogging PP spray nozzle. Water distribution is even. Well designed PVC Drift Eliminators are fitted to reduce Drift Losses. Square Fiber Glass Cooling Towers are provided with Inspection door for easy access for inspection and maintenance. Square tower can be installed in multi cell also MATERIALS USED FOR FRP SQUARE TYPE COOLING TOWERSQ FRP CASING Cooling Tower Casing is made of selected grade materials of tough Fiber Glass Reinforced Polyster and resins etc. An additional embossing is provided for extra strength of large Cooling Towers. Q HEADER PIPES The header pipe designed for proper distribution of water over the FILLS so that proper contact time for air to water is achieved. The header pipe is manufactured in G.I., P.P. with FRP moulded construction which makes it NON CORROSIVE TYPE & Long Lasting. Q WATER DISTRIBUTION NOZZLE We are offering low pressure drop, non-clogging, ABS make solid cone type nozzle for distributing the water on the fill pack area. Each nozzle is designed to operate on a water fluctuating load as good as 20%. Each nozzle can cater the service area of 1.2m x 1.2m at an inlet pressure of 0.3 kg. Per cm.sq. Q DRIFT ELIMINATOR CCS Drift eliminators, to reduce carry over losses through of moistures drop in the air stream. The individual drift eliminators of s-shaped corrugated sheets are bonded with subsequent layer to creat the structure. Q PVC HONEYCOMB FILLS PVC Honeycomb type fills having extended contact area. Splits incoming air and water into several streams spread evenly across the water cross section increasing heat transfer rate easy to replace. To select the right cooling tower, following specifications are required. Rate of water circulation (Flow rate):_______________ LPM or m3 / Hr. Hot water temperature:__________________________ 0C / F Cold water temperature:_________________________ 0C / F Ambient wet bulb temperature:____________________ 0C / F Applications:__________________________________

View Complete details

get quoterequest a call back
Fanless Cooling Towers

Fanless Cooling Towers

Rs 2 Lakh  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Tower MaterialFRP, Wooden, RCC
TypeInduced Draft Type, Natural Draft Type, Forced Draft Type
Splash loss and dust prevention capacity: Five-fold water blocker installed at the air vents of the tower top for liquid-water separation. In addition to dust prevention, the water splash loss is between 0.001~0.009% (as per spray pressure). Reduce more than 90% water splash loss than the traditional tower and reduce the transmission of Legionella bacteria Material of Construction: Structure: Is made from lined with FRP for corrosion resistance with heavy M.S.Angle/Tee/Channel sections and hot dipped galvanised or
Louvers: Are made from fibreglass reinforced plastics which ensures corrosion resistance and good mechanical properties.
Water Distribution Headers: Are made from “c” class galvanised pipe.
Nozzles: Are made from nylone-6 to give good corrosion resistance.
Nuts& Bolts: Are made from nylone-6 & M.S. Electroplated.

View Complete details

get quoterequest a call back
Oil Type Heat Exchangers

Oil Type Heat Exchangers

Rs 20,000  / onwardsGet Best Price
ApplicationHydraulic and Industrial Process
Medium UsedOil
Two types of oil heat exchanger are used to cool hydraulic oil: (1) shell-and-tube and (2) finned tube. The shell-and-tube oil heat exchanger has a series of tubes inside a closed cylinder. The oil flows through the small tubes, and the fluid receiving the heat (typically water) flows around the small tubes. Routing of the oil can be done to produce a single pass (oil enters one end and exits the other end) or a double pass (oil enters one end, makes a u-turn at the other end, and travels back to exit at the same end it entered).

Above is typically a shell and tube-type oil heat exchanger. The cooling water is pumped into the heat exchanger and flows around the tube bank. The hydraulic fluid, which is to be cooled, flows through the tubes. While flowing through the tubes, the fluid gives away heat to the water, thereby reducing its temperature. Advantages of Oil Type Heat Exchangers 1. They are very compact and cost-effective
2. They do not make noise
3. They are good in dirty environments.